Zyxel-communications Multi-service Access Platform MSAP2000 Manuale Utente Pagina 231

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 243
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 230
11. System Parameter Specification
MSAP2000 Technical Manual V3.0 11-2
11.2. STM-4
The following parameters will apply to module of SM4 (7.13).
Standard
specification
Complies with ITU-T G.957
Nominal Line
Rate
622.08Mbps
Optical Line Code
Binary Non-Return-to Zero
Application Code
S-4.1 , L-4.1, L-4.2, ER-1 or ER-2.
Connector
LC connector through SFP transceiver module
Transmission
Parameter
Application
Code
L (km)
λ (nm)
Laser Type
TX Power
(dBm)
RX Sens. (dBm)
IR-1/ S-4.1
20 1310 FP -8~-14 -28
LR-1/L-4.1
40 1310 FP 2 ~ -3 -28
LR-2/L-4.2
80 1550 DFB 2 ~ -3 -29
ER-1
120 1550 DFB 5~0 -34
ER-2
160 1550 DFB 5~1 -37
Vedere la pagina 230
1 2 ... 226 227 228 229 230 231 232 233 234 235 236 ... 242 243

Commenti su questo manuale

Nessun commento