Chapter 7 Loop Detection
MES-2110 User’s Guide
60
The following figure shows a loop detection enabled port N on switch A sending a
probe frame P to switch B. Since switch B is in loop state, the probe frame P
returns to port N on A. The Switch then shuts down port N to ensure that the rest
of the network is not affected by the switch in loop state.
Figure 27 Loop detection - Probe Frame
Note: After resolving the loop problem on your network you can re-activate the
disabled port via the web configurator or via commands (See the CLI Reference
Guide).
7.2 The Loop Detection Screen
Click Configuration > Loop Detection to open the following screen.
Figure 28 Configuration > Loop Detection